Filter Results By:

Products

Applications

Manufacturers

Current Probes

measure AC or AC-DC amperage without contacting conductors.

See Also: Current Sensors


Showing results: 196 - 210 of 293 items found.

  • Continuous LPR Corrosion Meter

    MS2001L - Metal Samples Company

    The MS2001L is a microprocessor-based, field-mountable corrosion rate meter. This versatile instrument measures the instantaneous corrosion rate and electrochemical current between the electrodes of any standard 2-electrode linear polarization resistance (LPR) probe. Corrosion rate is displayed on the LCD display.

  • Resistivity Meters

    SSR-MP-ATS - Integrated Geo Instruments & Services Private Limited

    The instrument design incorporates several innovative features and advanced techniques of digital circuitry to make it a reliable Geophysical tool providing high quality data useful for mineral and groundwater exploration and any other Geophysical applications. The SSR-MP-ATS sends the entire current into the ground without wasting power for constant current generation thus increasing the signal strength to probe deeper layers.

  • Rotating Bolthole Scanners

    Nortec - Evident Scientific

    Olympus extensive line of high performance eddy current scanners is available for use with Nortec Eddy Current Flaw Detectors. With a wide range of features consisting of speed ranges from 600 to 3000 rpm, frequency ranges from 100 Hz to 6 MHz, multiple connector types, and multiple probe types, our scanners offer a full range of application solutions.

  • Scanner Probe

    RFS set - Langer EMV-Technik GmbH

    The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.

  • 3 3/4 Digits AC/DC Current Digital-Clamp Multimeter

    KT7193 - Ketai instrument (kunshan) Ltd.

    ● 3 3/4 digits 3999 count● Extra high DC/AC current measurement● Data hold to capture measurements● Backlit display is easy to read under any light condition● AC current measurement up to 1500A● DC current measurement up to 1500A● DC/AC voltage, resistance, capacitance, frequency and temperature measurement● Diode and continuity test● Accessories included: 9V battery, carrying case, test leads, K typetemperature probe, English manual, gift box

  • Handheld Portable Multifunction Data Logger

    HD31 - Delta OHM S.r.L.

    Three independent input channels Automatic recognition of the probes - Measurement of Temperature Relative Humidity Atmospheric and differential pressure Air Speed Illuminance (lux) and Irradiance Carbon dioxide (CO2) – Air Quality Direct voltage (VP473 module) and current (IP472 module).

  • Flex Clamp Meters

    Greenlee Tools

    *Flex Clamp Current Probes expand existing meters *Compatible with most meters using universal banana leads*Flexible Coil adds accessibility - easily maneuvering around cables that are in hard to reach areas and large enough to thread around larger conductors

  • Differential Voltage Probes

    DP150/DP200pro - Powertek LLC

    The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.

  • Fuse Buddy Current Loop

    307M/308B - Electronic Specialties Inc.

    *Just clamp your current probe over the loop to access the amperage draw through a fused circuit. *Easy testing access, plugs right into fuse socket, no more hand made adapters. *Testing range 0-30 Amps - Do Not Exceed 30 Amps

  • Compact Coating Thickness Gauges

    MP0 Series - Helmut Fischer AG

    Gauge with integrated probe for easy handlingExcellent repeatability precisionLow influence of the permeability, electrical conductivity and shape of the substrate material (curvature, thickness, etc.)Patented conductivity compensation of the measured value (eddy current method)Quick one-hand operation: Simply place the instrument and read the measured valueTwo backlit LCD displays for convenient reading of the measured values in all instrument positions, even overheadDurable probe tip and robust housingAcoustical and optical signal of a measurement capture

  • Precision Picoprobe™ Micropositioner Probe Holder Kit

    PHD-3001A - High Power Pulse Instruments GmbH

    *Pulse force and pulse sense fixed pitch and flexible pitch RF probing solution for TLP/VF-TLP/HMM on-wafer measurements using Picoprobe™ Model 10*High peak current capability 80 A (100 ns)*DC – typ. 7 GHz bandwidth*Isolated probe-head ground shield for high pulse sense common mode signal rejection*Including fixed pitch replacement probe tip 50 Ω, right, 100 µm pad pitch*Including fixed pitch replacement probe tip 5 kΩ, left, 100 µm pad pitch*Including flexible pitch clamps plus 10-5k(0502)-125-W-1 and 10-50/30-125-W-1 replacement probe tips*True coaxial high-resolution 80:1 rotary probe-head for accurate probe tip adjustment

  • Complete Power Analysis System

    PK3564 - Summit Technology, Inc.

    PK3564 complete Power Analysis System includes PS3550 Power Analyzer, AC charger, Quick-Start manual, deluxe voltage leads, four eFX6000 flexible current probes, SD memory card, CAS3 hard-shell carrying case, PSM-A Software, and 1-year deluxe warranty.

  • TRMS Digital Multimeter

    HT65 - HT Italia Srl

    HT65 belongs to the TRMS CATIV 600V series of digital multimeters, made unique by the ability to measure DC voltage up to 1500V. It is also able to measure the temperature through the K probe, the AC / DC current with an external transducer, and the LoZ low impedance voltage input.

  • LOADpro Dynamic Test Leads

    180 - Electronic Specialties Inc.

    *LOADpro Test Leads load the circuit to see if current can flow. *By loading the circuit, LOADpro makes a voltage drop test “on the fly”. *Just press the switch – the test results can not lie. *Use LOADpro w/your DMM and follow our test method - you will find wiring faults quicker. *LOADpro Test Leads feature SteadyPin Probe Tips, which allows the probe to sit firmly on a male ECM or connector pin. *LOADpro are OEM approved – finds corroded circuits fast!

  • Near Field Probes 30 MHz up to 6 GHz

    XF1 set - Langer EMV-Technik GmbH

    The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.

Get Help